Chapter17
OAMConguration
TableofContents
EthernetOAMConguration.....................................................................................17-1
BFDConguration....................................................................................................17-7
17.1EthernetOAMConguration
TheZXA10C300supportsservicelayerOAMfunction,whichincludeslinkcontinuity
check,portloopbackdetection,linktrace,andalarmnotication.
17.1.1ConfiguringtheCCMFunction
CCMisusedtoensuresthecontinuitybetweenMPsinanMA.
Context
AMEGEndPoint(MEP)sendsContinuityCheckMessage(CCM)packetsperiodically,
whichensuresthecontinuityofMaintenancePoints(MPs)inthecorresponding
MaintenanceAssociation(MA).TheMPsthatreceivethepacketsneednottorespond.
CongurationData
Table17-1listthecongurationdataoftheCCMfunction.
Table17-1CongurationDataofCCMFunction
ItemData
MDlSessionID:1
lName:md1
lLevel:3
MAlSessionID:1
lName:ma1
lProtectionmode:VLANprotection
lPrimaryVLANID:100
LocalMEPlSessionID:1
lMEPID:1
lDirection:down
17-1
SJ-20130520164529-007|2013-06-30(R1.0)ZTEProprietaryandCondential