2. Select one alarm output channel in the Alarm Output dropdown list.
3. Set a name in for the alarm output (optional).
4. The Delay time can be set to 5sec, 10sec, 30sec, 1min, 2min, 5min, 10min or Manual. The delay time
refers to the time duration that the alarm output remains in effect after alarm occurs.
5. Click the tab to enter the arming schedule setting interface. The time schedule
configuration is identical to configuring an arming schedule for motion detection. Refer to Section 5.2.1
Configuring Motion Detection for more details.
Figure 5-19 Alarm Output Settings
6. If desired, copy the settings to other alarm outputs.
7. Click to save the settings.
HANDLING EXCEPTIONS
Available exception types: HDD full, HDD error, Network disconnected, IP address conflict and Illegal camera
login.
Steps:
1. Enter the Exception settings interface: Configuration > Event > Basic Event > Exception
2. Check off the corresponding checkbox for desired Exception alarm linkages. Refer to Section 5.2.1
Configuring Motion Detection for details on configuring linkage methods.