Chapter 2 – AC 80 Hardware and Connections
AC 80 User’s Manual 2-15
(Length 3 m )
X1
CDP 80
CONTROL PANEL
D oor P anel M ounting
(O ptional)
CDP 80
CONTROL PANEL
X1
(Length m ax 10 m )
Male-to-Male
Extension
C onnector
X3
X1
NDPI-21
CONTROL PANEL
IN T E R F A C E
X4
X2
N ote 1: C D P 80 C ontrol Panel can optionally be connected
to X 4 o r X 2 o n N M B C -0 1 u n it.
N ote 2: The bus m ust be term inated at both ends. AC 80
contains fixed term ination. Term ination on the first
N M B C -01 unit m ust be sw itched O FF.
N ote 3: N M BC -01 can also be the last ´device´ in the bus.
In that case term ination m ust be sw itched O N .
N ote 4: If G O P is the last device in the bus, term ination is
im plem ented w ith a jum per betw een the pins 2 & 3
o f X 2 .
N ote 5: In bus cable tw o parallel connected pairs are used
for 24 V D C . (R ecom m ended practise.)
See page 2/2 for 3-pair w iring.
The m axim um loop resistance of 24 V w iring betw een
G O P G raphical O perating P anel and pow er supply is 5 ohm .
(2.5 ohm for tw o panels.) The loop resistance of single
JA M A K pair is m ax 8.1 ohm /100 m .
N ote 6: The m axim um total length of the M odbus is 300 m .
N ote 7: The m axim um distance betw een C D P 80 and AC 80 is 30 m .
X1
Ch2
+
-
AC 80
APPLICATIO N
CONTROLLER
PO W ER SUPPLY
2 4 ...2 8 V D C
(M ax 10 A )
ALARM
PRIN TER
X3
X2
X1
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
X3
X2
NM BC-01
MODBUS
T E R M IN A T IO N U N IT
GOP
GRAPHICAL
OPERATING PANEL
NAPI-01
ALARM
P R IN T E R IN T E R F A C E
C entronics C able
(Length m ax 3 m )
NCPC-30 Control
Panel Cable, AC 80
C ontrol P anel
C able (B lack),
3AFE 6404 4761
24 V
0 V
24 V
0 V
SHIELD
DGND
SHIELD
DATA A (+)
DATA B (-)
SHIELD
+24 V
0 V
+24 V
0 V
SHIELD
DGND
SHIELD
DATA A (+)
DATA B (-)
SHIELD
+24 V
0 V
+24 V
0 V
SHIELD
DGND
SHIELD
DATA A (+)
DATA B (-)
SHIELD
SHIELD
RS485 A+
TERM IN
RS485REF
SHIELD
RS485 B-
24 V
0 V
SHIELD
RS485 A+
TERM IN
RS485REF
SHIELD
RS485 B-
24 V
0 V
IN
IN
OUT
OUT
NCPC-30 Control
Panel C able, A C 80
(Length 3 m )
X1
JA M A K
4 x (2 + 1 )x 0 .5
JA M A K
4 x (2 + 1 )x 0 .5
JA M A K
4 x (2 + 1 )x 0 .5
24 V
0 V
24 V
0 V
DGND
DATA A (+)
DATA B (-)
(2 P a irs )
N o te 4
(2 P a irs )
24 V
0 V
DGND
DATA A (+)
DATA B (-)
24 V
0 V
DGND
DATA A
DATA B
(2 P a irs )
To next device
(O KI M icroline 280)
230 V A C
(2 P a irs )

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB Advant Controller 80 and is the answer not in the manual?

ABB Advant Controller 80 Specifications

General IconGeneral
BrandABB
ModelAdvant Controller 80
CategoryController
LanguageEnglish

Related product manuals