1.3.7 The unit is sensitive to ESD
Description
ESD (electrostatic discharge) is the transfer of electrical static charge between two
bodies at different potentials, either through direct contact or through an induced
electrical field. When handling parts or their containers, personnel not grounded
may potentially transfer high static charges. This discharge may destroy sensitive
electronics.
Safe handling
NoteAction
Wrist straps must be tested frequently to ensure
that they are not damaged and are operating cor-
rectly.
Product manual - IRC5
Product manual - IRC5 Panel Mounted
Controller
Use a wrist strap. The wrist strap
button is located inside the control-
ler.
1
The mat must be grounded through a current-limit-
ing resistor.
Use an ESD protective floor mat.2
The mat should provide a controlled discharge of
static voltages and must be grounded.
Use a dissipative table mat.3
34 Product manual - IRB 2400
3HAC022031-001 Revision: P
© Copyright 2004-2018 ABB. All rights reserved.
1 Safety
1.3.7 The unit is sensitive to ESD

Table of Contents

Other manuals for ABB IRB 2400/10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB IRB 2400/10 and is the answer not in the manual?

ABB IRB 2400/10 Specifications

General IconGeneral
BrandABB
ModelIRB 2400/10
CategoryRobotics
LanguageEnglish

Related product manuals