2.4.4 Installation of limit switch, axis 3
General
The working range of axis 3 can be limited by fitting an electrical switch on the
gearbox axis 3, which senses the position via a cam. The system parameter
configuration must also be updated.
Mounting of eletrical stop
Following illustration shows how to fit the electrical stop.
xx0200000211
80 Product manual - IRB 2400
3HAC022031-001 Revision: P
© Copyright 2004-2018 ABB. All rights reserved.
2 Installation and commissioning
2.4.4 Installation of limit switch, axis 3