5 Calibration information
5.1. Introduction
4033HAC022033-001 Revision: K
© Copyright 2004-2011 ABB. All rights reserved.
5 Calibration information
5.1. Introduction
General
This chapter includes general information about the different calibration methods and also the
detailed procedures that do not require specific calibration equipment.
When the robot system must be recalibrated, it is done according to the documentation
enclosed with the calibration tools.
When to calibrate
The system must be calibrated if any of the following situations occur.
The resolver values are changed
If resolver values are changed, the robot must be recalibrated using the calibration methods
supplied by ABB. Calibrate the robot carefully with standard calibration. The different
methods are briefly described in the section Calibration methods on page 404, and further
detailed in separate calibration manuals.
If the robot has absolute accuracy calibration, it is also recommended, but not always
necessary to calibrate for new absolute accuracy.
The resolver values will change when parts affecting the calibration position are replaced on
the robot, for example motors or parts of the transmission.
The revolution counter memory is lost
If the revolution counter memory is lost, the counters must be updated. See Updating
revolution counters on page 408. This will occur when:
The battery is discharged
A resolver error occurs
The signal between a resolver and measurement board is interrupted
A robot axis is moved with the control system disconnected
The revolution counters must also be updated after the robot and controller are connected at
the first installation.
The robot is rebuilt
If the robot is rebuilt, for example, after a crash or when the reach ability of a robot is changed,
it needs to be recalibrated for new resolver values.
If the robot has absolute accuracy calibration, it needs to be calibrated for new absolute
accuracy.
工控帮助教小舒QQ2823408167
长沙工控帮教育科技有限公司

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB IRB 7600 Series and is the answer not in the manual?

ABB IRB 7600 Series Specifications

General IconGeneral
BrandABB
ModelIRB 7600 Series
CategoryRobotics
LanguageEnglish

Related product manuals