Start-up 31
Immediate apply mode
It is possible to override the normal behavior for valid on reset objects to allow objects
that are linked to parameters (keywords) to be written with immediate effect. This
provides improved usability in PLC programs since it allows parameter access via
objects. To enable immediate apply mode, set object CFG_ImmediateApply_BOOL
(3004). Parameter values set while in immediate apply mode are volatile and will be
reset to their default / configuration value after a reset. To save the object as a
configuration value, write the value 0x65766173 [evas/save] to object 1010:01.
Deleting the stored configuration
Write 0x64616F6C [daol/load] to 1011:01 to delete the stored configuration and set all
objects to their default values.
Configuration object operations
Default value
Default value
Configuration
value
Non-volatile
stored value
Current value
Value of object
in RAM;
changed locally
or by master
Mint
Live value in
profiler /
scheduler
OBJECT DICTIONARY PARAMETER
TABLE
Set parameter
Get parameter
Set/Get object with
immediate apply enabled
Set/Get object
Set/Get configuration
Reset configuration
Apply configuration
PARAMETERSAVE
(write object 1010)
FACTORYDEFAULTS
(write object 1011)
123
123
123
123
123
123
123
123
123
123123
123
123
123
123

Table of Contents

Other manuals for ABB MotiFlex e180

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB MotiFlex e180 and is the answer not in the manual?

ABB MotiFlex e180 Specifications

General IconGeneral
BrandABB
ModelMotiFlex e180
CategoryController
LanguageEnglish

Related product manuals