Operation Manual / TPS44-F.. - TPS61-F..
2 Safety / 2.8 Deflagration on gas engines
© Copyright 2020 . All rights reserved. HZTL2412_EN Rev.G March 2020
Hazards due to electrical components
WARNING
Hazards due to electrical components
Electrical components operate with voltages which can present hazards
to humans.
u All work on or with electrical components may only be performed by
trained specialists.
u Heed any country-specific regulations.
2.8 Deflagration on gas engines
ABB turbochargers can withstand a deflagration with a transient pres-
sure increase of 12bar.
ABB Turbocharging recommends that, following a deflagration event,
the turbocharger undergoes an inspection of the following points:
¡ Position of the turbine and compressor casings to the bearing casing
¡ Shifting of the bearing casing in relation to the bracket
¡ Cracks in casings
If during external inspection anomalies are found or if a particularly
strong deflagration event has taken place, it is also recommended to
check the bearings of the turbochargers before the next start. This in-
spection and evaluation must be carried out by an ABB Turbocharging
Service Station.
Page 25 / 113