Command WCLRE1
Response RCLRE0
Query not available
Response not available
Clear event log
Parameters not available
Command not available
Response not available
Query REVNT
Response REVNTxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Alarm query
Parameters xxxxxxxxxxxxxxxxxxxxxxxxxxxxx – alarm list (1 = alarm,
0 = OK). The alarms are listed in the following order:
1. Status of major alarms
2. Status of non-major alarms
3. Clock stopped
4. Over-temperature
5. Test faults
6. Not used
7. Encoder comms failure
8. HPA comms failure
9. up-converter comms failure
10. Fan 1 fault
11. Fan 2 fault
12. Encoder video lock fault
13. Encoder audio A lock fault
14. Encoder audio B lock fault
15. Encoder remux in active
16. HPA A comms failure
17. HPA B comms failure
18. HPA A interlock failure
19. HPA A over temperature
20. HPA A helix failure
21. HPA A high output failure
22. HPA A low power failure
23. HPA A reflected power failure
24. HPA A PSU failure
25. HPA B interlock failure
26. HPA B over temperature
27. HPA B helix failure
28. HPA B high output failure
29. HPA B low power failure
30. HPA B reflected power failure
31. HPA B PSU failure