Advent Communications
209298 - DVE5000 Technical Operation Handbook - CL140042 Page 74 of 110
8.6.6 Remote Exciter settings
Command WCARRx
Response RCARRx
Query RCARR
Response RCARRx
Carrier
Parameters x – carrier state (0 – OFF, 1 – ON, 2 – OFF due to an
alarm)
Command WCCARx
Response RCCARx
Query RCCAR
Response RCCARx
Modulation
Parameters x – modulation state (1 = ON, 0 = OFF)
Power Null Command WPWR0x
Response RPWR0x
Query not available
Response not available
Parameters x – power null parameter (0 = OFF, 6 = ON)
10 MHz Reference Command WUREFx
Response RUREFx
Query RUREF
Response RUREFx
Parameters x – 10MHz ref state (0 = OFF, 1 = ON)
Transmit band Command WRBNDx
Response RRBNDx
Query RRBND
Response RRBNDx
Parameters x – band (0 = 70MHz, 1 = L, 2 = C, 3 = X. 4 = Ku1, 5 =
Ku2, 6 = Ku3, 7 = Ku6, 8 = DBS1, 9 = DBS2)
L-Band Transmit
frequency
Command WRFRQxxxxx.xxxx
Response RRFRQxxxxx.xxxx
Query RRFRQ
Response RRFRQxxxxx.xxxx
Parameters xxxxx.xxxx– frequency in 100Hz steps