Advent Communications
209298 - DVE5000 Technical Operation Handbook - CL140042 Page 73 of 110
Command not available
Response not available
Query RELOG
Response RELOGxxx
Event log query
Parameters xxx… is a list of the 10 most recent events in the event
log (if there are fewer than 10 events then the data will
be padded with ‘-‘s).
The format of each entry is:
abhhmmssDDMMYY!
Where
a – event type
b – status flag (A = active alarm, C = cleared alarm)
hh – hours
mm minutes
ss seconds
DD day
MM – month
YY – year
xx.x – unit temperature when the event occurred
! – delimiter
The event type is as follows:
D - UNIT POWERED UP
E - EVENT LOG CLEARED
F - SOFTWARE RESET
G - UNIT POWERED DOWN
H - Unreg. Supply out of range
I - Clock stopped
J - NVRAM Battery low
K - Over-temperature
L - 5v Supply out of range
M - 18v Supply out of range
N - 8v Supply out of range
O - -12v Supply out of range
P - Unit service required
Q - PLO voltage out of range
R - PLO fault
S - SLO 1 fault
T - SLO 2 fault
U - Encoder comms failure