Rockwell Automation Publication 750-QS001A-EN-P - March 2015 13
Step 3: Power Up, Configure the Drive, and Spin the Motor Shaft
Drive Setup
Follow these steps to set up each of your drives.
Enter Motor Nameplate Data
1. From the Main Powerup Screen, access parameter 25 [Motor NP Volts].
• Press the soft key.
• Enter 25 using the numeric keys.
• Press the soft key.
2. Use the numeric value from the Motor Nameplate data gather in Step 1: Gather Required Information under
Record
Motor Nameplate Data on page 7 to verify the value on the screen. If a change is required,
• Press the soft key.
• Enter the nameplate voltage numeric value using the keypad.
• Press the soft key.
3. Press on the keypad to advance to the next parameter num
b
er, and continue to enter the remaining motor data
gathered in Step 1: Gather Required Information in this order.
• Parameter 26 [Motor NP FLA]
• Parameter 27 [Motor NP Hertz]
• Parameter 28 [Motor NP RPM]
00
Stopped
0.000 Hz
AUTO
PowerFlex 753
480V 4.2A
20F...B4P2
ESC REF TEXT
F
PAR#
PowerFlex 753 Powerup Screen
Stopped
0.000 Hz
AUTO
PowerFlex 753
Jump to Param #
ESC
F
ENTER
▲▼
Parameter Screen
Stopped
0.000 Hz
AUTO
PowerFlex 753
Jump to Param #
25
ESC
F
ENTER
▲▼
Parameter Screen
Keypad
EDIT
Stopped
0.000 Hz
AUTO
Port 00 Dev Param 25
Motor NP Volts
480.00 VAC
ESC EDIT
F
PAR#
Edit Motor NP Volts Screen
Keypad
E S C ENTER
Stopped
0.000 Hz
AUTO
F
Edit Mtr NP Volts
480.00 VAC
0.10 << 552
Motor NP Volts Screen