EasyManuals Logo
Home>Ambirad>Remote Control>SmartCom2

Ambirad SmartCom2 User Manual

Default Icon
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
SmartCom
2
Control Installation and User Manual
2
SmartCom
2
Control Installation and User Manual
3
CONTENTS
Introduction ........................................................................................................................... 3
1 Technical Speci cations ................................................................................................ 3
1.1 Operating Environment ................................................................................... 3
1.2 Performance Speci cations ............................................................................. 3
1.3 Lite Version Electrical Specifi cations ............................................................... 4
1.4 Standard Version Electrical Speci cations ..................................................... 4
1.5 Advanced and Network Version Electrical Speci cations ............................ 4
2 Installation Instructions ............................................................................................... 5
2.1 Mounting the Control Assembly ..................................................................... 5
2.2 General Wiring Specifi cations ......................................................................... 7
2.3 Lite Version Wiring Connections ..................................................................... 7
2.4 Standard Version Wiring Connections ........................................................... 8
2.5 Advanced Version Wiring Connections .......................................................... 9
2.6 Network Version Wiring Connections .......................................................... 10
3 Operating Instructions ............................................................................................... 11
3.1 The buttons ..................................................................................................... 11
3.2 The display ....................................................................................................... 11
3.3 Setting the clock ............................................................................................. 12
3.4 Setting the operating modes ........................................................................ 12
3.5 Setting the program (on/off times) .............................................................. 13
3.6 Setting the day and night temperatures ..................................................... 15
3.7 Optional Password (PIN protection) ............................................................. 15
3.8 Networked Controllers (SC-NET only) .......................................................... 16
3.8.1 Setting up the network . ................................................................................. 16
3.8.2 Operating the master controller ................................................................... 17
3.9 Checking the temperature ............................................................................. 17
3.10 Setting a temporary Holiday period ............................................................. 17
3.11 Setting a temporary overtime extension period ........................................ 18
3.12 Setting a temporary vent period .................................................................. 18
3.13 Error message:- Lockout ................................................................................ 19
3.14 Battery Type & Replacement ........................................................................ 19
3.15 Optimum Start and Optimum Stop .............................................................. 19
4 Engineer Functions ...................................................................................................... 20
4.1 General Password (PIN Protection) ............................................................... 20
4.2 Programming The Engineer Functions ......................................................... 21
4.3 The Engineer Variables ................................................................................... 21
4.4 External Inputs ................................................................................................ 23
4.5 Default Priority Settings ................................................................................. 23
INTRODUCTION
This manual describes the Installation and Operation of the ‘SmartCom
2
’ control
unit. NB This control must be installed according to the current IEE Wiring
Regulations and should include full disconnection means and fusing appropriate to
the connected loads.
1 TECHNICAL SPECIFICATIONS
1.1 Operating Environment
Operating temperature range: 0º C to 40º C
Operating humidity range: 0 to 90% RH.
Control IP rating: IP30
Pollution degree: II environment
Control safety construction: class II
Mains supply: 230Vac nominal, 200Vac to 265Vac actual, 50Hz.
On board supply fuse: 1AT
Rated impulse voltage: 2500V
1.2 Performance Specifi cations
An independently mounted electronic control for surface mounting.
Operation is by Class A software and Type 1A action.
The mains supply to the electronic circuit is protected by a time delay fuse.
Flame failure input: 230Vac nominal, 200Vac to 265Vac actual, 50Hz. Presence of
voltage indicates ame failure.
The burner reset relay output is either Live or Neutral which is selected by a plug-in
jumper (Live only in case of Lite version).
Remote volt-free switch outputs will be 24Vdc/5mA
The built-in room temperature sensor has a measuring range of 0º C to 30º C with
a resolution of 0.2º C.
Temperature sensor readings can be offset to allow for errors due to sensor
tolerances and location. NB Frost protection readings are also affected by offsets.
Built-in and remote
room temperature sensor
Measuring range: 0 – 30º C.
Resolution: 0.2º C.
Untrimmed accuracy over range: +/- 1.4º C.
Accuracy over range with offset:
(See section 4.3)
+/- 0.6º C.
Unless well ventilated, heat generated in the control may cause the built-in
sensor to over-read temperatures.
Remote duct temperature
sensor
Measuring range: 10° – 60º C.
Resolution: 0.2º C.
Accuracy over range: +/- 3.0º C.