Appendix C: Troubleshooting
173
MVP-5100/5150 5.2" Modero Viewpoint Touch Panels
Appendix C: Troubleshooting
Overview
This section describes the solutions to possible hardware/firmware issues that could arise during the common
operation of a Modero touch panel.
Panel Doesn’t Respond To Touches
Symptom: The device either does not respond to touches on the touch screen or does not register the touch as
being in the correct area of the screen.
If the screen is off:
If the screen is off:
The device may be in Standby Mode. Press and hold the display screen to wake up the panel.
The device may be in Shutdown Mode. Press and hold the top and bottom of the navigation wheel
until the device turns on.
The device battery may be drained. Place the device into a Table Charging Station or a Wall Charging Station,
or connect it to its included power source to recharge the battery.
If the screen is on:
The protective laminate coating may still be on the LCD. Verify that the coating on the LCD is
removed before beginning any calibration process. The protective cover makes calibration difficult
because the device cannot calibrate on specific crosshairs when the sheet is pressing on the whole
LCD.
The previous calibration may be off. Reset the device calibration, as explained in the Calibrate
Page section on page 78.
Battery Will Not Hold Or Take A Charge
Symptom: The battery will not hold or take a charge and shows no indication of charging, either on the
bargraphs or in the Battery Setup page.
To keep the battery from being damaged from operating at too low a level, the firmware places it into a
protected state.
The panel must have the latest firmware. If it doesn’t, the firmware can be found at www.amx.com Dealers/
Tech Center > Firmware Files.> Modero.
1. Load the firmware into the panel, using NetLinx Studio.
2. After loading the firmware, power cycle the MVP (this is a complete power cycle, not a Reboot). The
panel will now show the current firmware version within the Setup > Panel Information page.
3. Connect the power supply to the panel. You will see 2 warning messages on the display.
The first one warns that the battery is low and must be charged.
The second warning tells you that the battery is in a protected mode.
4. Wait a few minutes and then check the Battery Settings page on the device to see any charging activity on
the bar graphs. (For more information, refer to the Power Management Page section on page 51.)
The "Sensor" device in the Online Tree tab below the MVP panel should show v1.24 or higher after the
upgrade, as shown in FIG. 94:
FIG. 94 "Sensor" device in the Online Tree tab

Table of Contents

Other manuals for AMX MVP-5100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX MVP-5100 and is the answer not in the manual?

AMX MVP-5100 Specifications

General IconGeneral
BrandAMX
ModelMVP-5100
CategoryTouch Panel
LanguageEnglish

Related product manuals