CONFIDENTIAL
30
30” BUILT-IN REFRIGERATOR / REVISION NUMBER: 00
10.1. E0 Freezer Air Sensor Error
E0:
Freezer
AIR
SENSOR
ERROR
Check the cables connected to the pins
number 3 and 4 of the control board
sensor socket (KN2)
If the cables are came out, correct
them, turn on the fridge and check
i
display?
Dismantle the KN2 socket from the
control board. Measure the3 sensor
resistance from pins number 3 and 4 of
the socket and check if it is between 5K
and 200K
Is the value
appropriate?
Change the control board.
Change the faulty sensor by looking at
the sensor change SUF