36
The boiler is delivered with pre-set values described
i
n menus
3 a
nd
4.
All settings must only be changed by the installer or
a
qualified person. To gain access to the setting
buttons please, open the front control panel cover
P.
(Fig. 42) and follow the instructions below.
17. Adjustments and settings
DISPLAY
2nd digit
P
1st digit
3rd digit
4th digit
On/Off push button Comfort button
Reset push button
Menu button - button
+ button
Setting button
Fig. 43
Fig. 42
Pressing the, comfort, reset, menu, +, -, or setting buttons will make the display light. The light will go out 30 seconds after the
last button has been pressed.
To gain access to the setting menus press the and buttons together for 5 seconds. (Fig. 43). Menu 1 is displayed on
the 1st digit.
Changing the menu :
Press the Menu button (Fig. 43). The menu number is displayed for 3 seconds. Press the menu button again to change
to the next Section.
Setting a parameter in a section :
Press the or button to change from between sections.
Note : When you arrive at the last section of a menu, pressing the button will change to the the 1st section. When you
are at the first section, pressing the button will change to the last section of the menu.
Changing section in a menu (available only for menu 3 and 4) :
Press the setting button
to enter the modification mode, The 3rd and 4th digits will be flashing, press the or
button to select the correct value then press the setting button to select this modification and to exit the setting mode. The
3rd and 4th digit stop flashing.
Recalling the basic configuration :
Select menu 3 or 4 then press the and
buttons together for more than 5 seconds. The digits will flash
CM for a while
to indicate that the operation is completed.
Clearing Menu 1 (default register) :
Select menu 1 then press the and
buttons together for more than 5 seconds. The digits will flash
CM for a while to
indicate that the operation is completed.
Note : To exit from setting mode, leave the boiler for approx. 1 minute, the display will switch back to user mode.