In air receiver/oil separator (AR), most of the oil is removed from the air/oil mixture by centrifugal action.
The remaining oil is removed by oil separator (OS). The oil collects in the lower part of air receiver/oil
separator (AR), which serves as an oil tank.
The oil system is provided with a thermostatic bypass valve (BV). When the oil temperature is below its set
point, bypass valve (BV) shuts off the supply to oil cooler (Co) and the oil cooler is bypassed.
Air pressure forces the oil from air receiver/oil separator (AR) through oil filter (OF) and oil stop valve
(Vs) to compressor element (E).
Bypass valve (BV) starts opening the supply from cooler (Co) when the oil temperature has increased to
the set point. At approx. 15 ˚C (27 ˚F) above the set point, all the oil flows through the oil cooler.
Oil stop valve (Vs) prevents the compressor element from flooding with oil when the compressor is
stopped. The valve is opened by element outlet pressure when the compressor is started.
2.4 Cooling system
Flow diagram
Cooling system, air-cooled compressors
References Description
A Intake air
B Air/oil mixture
C Oil
D Wet compressed air
E Condensate
Instruction book
API603130 15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA 55+ and is the answer not in the manual?

Atlas Copco GA 55+ Specifications

General IconGeneral
BrandAtlas Copco
ModelGA 55+
CategoryAir Compressor
LanguageEnglish

Related product manuals