3.23 Programmable settings
Parameters: unloading/loading pressures for compressors without dryer
Minimum
setting
Factory
setting
Maximum
setting
Unloading pressures
Loading pressures
Parameters: unloading/loading pressures for GA Workplace Full-Feature
Minimum
setting
Factory
setting
Maximum
setting
Unloading pressures
Loading pressures
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Motor running time in star sec 5 10 10
Load delay time (star-delta) sec 0 0 10
Number of motor starts starts/day 0 240 240
Minimum stop time sec 0 20 30
Programmed stop time sec 0 3 20
Power recovery time (ARAVF) sec 10 10 3600
Restart delay sec 0 0 1200
Communication time-out sec 10 30 60
Protections
Minimum
setting
Factory
setting
Maximum
setting
Compressor element outlet temperature
(shut-down warning level)
˚C 50 110 119
Compressor element outlet temperature
(shut-down level)
˚C 111 120 120
Minimum
setting
Factory
setting
Maximum
setting
Oil separator (pressure difference) bar 0 1 2
Oil separator (delay at signal) sec 0 10 20
Instruction book
API603130 51

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA 55+ and is the answer not in the manual?

Atlas Copco GA 55+ Specifications

General IconGeneral
BrandAtlas Copco
ModelGA 55+
CategoryAir Compressor
LanguageEnglish

Related product manuals