Service indicator
Recommendations
1. Never remove the filtration element while the compressor is running.
2. For minimum downtime, replace the dirty element by a new one.
3. Discard the element when damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. Release the snap clips of air filter (AF) and remove the dust trap and the air filter element. Clean the
trap. Discard the filter element.
3. Fit the new element and the cover.
4. Reset service indicator (1) by pushing the knob in the extremity of the body.
5. Reset the air filter service warning.
Consult section Status data menu to reset the service warning on Elektronikon II regulators.
1. Stop the compressor. Switch off the voltage.
2. Remove the side panel.
3. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If
necessary, clean the cover.
4. Fit the new element and the cover.
5. Reset the air filter service warning.
7.3 Oil and oil filter change
Warning
The operator must apply all relevant Safety precautions.
Instruction book
API603130 77

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA 55+ and is the answer not in the manual?

Atlas Copco GA 55+ Specifications

General IconGeneral
ModelGA 55+
CategoryAir Compressor
Power55 kW
Working Pressure7.5 - 13 bar
Height1800 mm
Cooling MethodAir-cooled
Drive TypeDirect driven
Sound Level70 dB(A)