Service indicator
Recommendations
1. Never remove the filtration element while the compressor is running.
2. For minimum downtime, replace the dirty element by a new one.
3. Discard the element when damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. Release the snap clips of air filter (AF) and remove the dust trap and the air filter element. Clean the
trap. Discard the filter element.
3. Fit the new element and the cover.
4. Reset service indicator (1) by pushing the knob in the extremity of the body.
5. Reset the air filter service warning.
Consult section Status data menu to reset the service warning on Elektronikon II regulators.
1. Stop the compressor. Switch off the voltage.
2. Remove the side panel.
3. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If
necessary, clean the cover.
4. Fit the new element and the cover.
5. Reset the air filter service warning.
7.3 Oil and oil filter change
Warning
The operator must apply all relevant Safety precautions.
Instruction book
API603130 77