• The number of load cycles
Procedure
Starting from the Main screen (see Main screen menu):
• Press the key ‘Menu’ (F1).
• Press the arrow down key (1) until ‘Counters’ is followed by a horizontal arrow.
• Press the tabulator key (2) to activate the menu.
• By pressing the arrow key (1), the above-mentioned data can be found.
Example of a Counters screen
‘Running Hours’
‘hrs’ ‘2107 hrs’
‘Menu’
F1 F2 F3
3.13 Test menu
Control panel
Function
To carry out a display test, i.e. to check whether the display and LEDs are still intact.
Procedure
Starting from the Main screen (see Main screen menu):
• Press the key ‘Menu’ (F1).
• Press arrow down key (1) until ‘Test’ is followed by a horizontal arrow.
• Activate the menu by pressing the key (2).
• The option ‘Display test’ will be followed by a horizontal arrow.
• To test the display, press the key (2). During testing, the regulator will generate a series of patterns on
the display which enable the operator to check that each pixel still functions normally; at the same
time the LEDs are lit.
Instruction book