6 Basic Operations (Counter/Timer/Communication)
© Copyright Reserved Autonics Co., Ltd. 37
6 Basic Operations (Counter/Timer/Communication)
6.1 Operations and functions
※1: If no key is touched for 60 sec,the counter will return to RUN mode without being restored
setting value in setting value change mode.
6.1.1 Setting value change mode (Counter/Timer)
In RUN mode, press the key to enter setting value change mode.
Even if changing the setting value, input operation and output control will continue. In
addition, the setting value could be set to 0 and the output of 0 setting value turns ON.
When entering the setting value change mode, the counting value display component
displays present value and the setting value display component displays the setting value.
According to the output mode, setting value could not be set to 0. (When setting to 0,
setting value "0" will flash 3 times.)
※In case of 1-stage preset, indicator model, PRESET2 displays PS and PRESET1 does not
displayed.
※Press the key to save the changing setting value at each parameter and it moves the next
parameter or returns in RUN mode.