7 Counter Mode
48 © Copyright Reserved Autonics Co., Ltd.
7.3 Output mode
Output
mode
Input mode
Up, Up-1, 2 Down, Down-1, 2
Up/Down A, B, C
F [F]
After count-up,
counting display value increases or decreases until reset signal is
applied and retained output is maintained.
N [N]
After count-
up, counting display value and retained output are maintained until
reset signal is applied.
C [C]
When count-up, counting display value will be reset and count simultaneously.
OUT1 retained output will be off after OUT2 one- shot time.
The one-shot output time of OUT1 one-shot output time is operated regardless
of OUT2 output.
R [R]
After count-up, counting value display is reset after one-shot output time of OUT2
and it counts simultaneously.
OUT1 retained output will be off after OUT2 one-shot time.
OUT1 one-shot output time is operated regardless of OUT2 output.