Product overview
Version: 2.1 ─── 15AS2000
Ordering options
Ordering options are defined via the type key and must be ordered
separately. The listed components cannot be retrofitted.
3.4.1
Feather key
A feather key transmits torque to an output element.
The stepper motors of flange size N3 are equipped with feather key
groove and fitted feather key according to DIN6885. The rotor is bal-
anced with half a feather key according to DIN ISO
21940-32:2012-08.
Intended use
Beckhoff stepper motors from the AS2000 series are specially de-
signed for use as actuators in handling devices, textile machines,
machine tools, packaging machines and similar machines. They are
intended to be controlled and operated in terms of speed and posi-
tion by Beckhoff stepper motor output stages.
The stepper motors from the AS2000 series may be operated exclu-
sively for the activities foreseen and defined in this documentation,
taking into account the prescribed environmental conditions.
The components are to be installed in electrical systems or ma-
chines and only put into operation as integrated components of the
system or machine.
Read the entire drive system documentation:
• Translation of the original instructions
• Original operating instructions for the stepper motor terminals
and stepper motor modules
• Complete machine documentation provided by the machine
manufacturer
Non-observance of the documentation content may result in dam-
age to the product and exclusion of liability.
Improper use
Any use exceeding the permissible values specified in the "Techni-
cal data", [Page16] is considered improper and therefore prohib-
ited.
Beckhoff stepper motors from the AS2000 series are not suitable for
use in the following areas:
ATEX zones without suitable housing
Areas with aggressive environments, for example aggressive
gases or chemicals
The relevant standards and directives for EMC interference emis-
sions must be complied with in residential areas.