Fault correction
56 ─── Version: 2.1AS2000
Number Cause Solution
11 Short circuit or earth leakage in the motor Replace defective motor, then measure and check.
12 Insufficient power supply Check the settings in the configuration and read out the
electronic type plate of the motor again
13 Interruption or crushing in the feedback cable Check cables for broken wire or crushing. Replace defective
cables, then measure and check
14 Feedback connector not fitted correctly Check the position of the feedback connector
Loose fit of the feedback connector or no contact of the plug
contacts with the power socket of the motor.
Check the connector assembly. Contact Beckhoff Service if
necessary