4.2.6
DIVAR 2000 / DIVAR 3000 / DIVAR
18 en | Installation
5000
Back panel connectors DIVAR hybrid 3000
16 BNC for connecting max. 16 analog cameras
Max. 16 IP cameras connected via external switch (if no
analog cameras are connected, an extra 16 IP cameras can
be connected)
RJ45 Ethernet connection (10/100/1000Base-T according to
IEEE802.3)
1 D-SUB (Monitor output)
1 HDMI (Monitor output)
1 HDMI (output for spot monitor)
16 screw terminal inputs, cable diameter AWG26‑16 (1.29–
0.4 mm)
4 screw terminal outputs, cable diameter AWG26‑16 (1.29–
0.4 mm)
4 RCA (Audio inputs)
1 RCA (Audio output)
1 RCA (Audio input)
Screw terminal output (Dome control)
DB9 male, 9-pin D-type (Dome control)
One front (2.0) and two rear (3.0) USB connectors for mouse
or USB memory device
Power input with On/Off 12 VDC (5 A)
switch AC input adapter: 100~240 VAC, 50-60 Hz, 1.5 A
Ground connection
2016.09 | v1.0 | AM18-Q0717 Operation Manual Bosch Security Systems