25Bosch Security Systems 10/22 BLCC615U
Solution 6000-IP User Guide
Inputs > Input Testing >
Walk Test A Single Zone
MENU 3-9-1
This menu allows you to select a single zone to be tested
via walk test.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [3] + [9] + [1].
The keypad will display a list of zones that are
available to be tested via walk test.
2. Use the [] and [] keys to select the zone that
you want to walk test, then press [OK] to select.
Alternatively, you can enter the zone number, then
press [OK].
The keypad will display the zone to be tested.
To test zone Zn1
open then close
Zone 1 Name
Press OK or MENU
3. Open and close the zone that needs to be tested.
When the zone has been successfully faulted and
restored, the keypad will display:
Zn1 Zone 1 Name
Test Successful
Press OK or MENU
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Outputs
The control panel can have up to a maximum of 37 outputs.
Five outputs are available as standard with an additional 32
available when the optional output expanders are fitted.
Your installer will advise you on the exact makeup and
configuration of your system.
Outputs > Commands >
Output Status
MENU 4-0-0
This menu allows you to view the status of each output.
Enter programming mode (PIN + MENU) then,
1. Ensure that the system is turned off.
2. Press [MENU] + [4] + [0] + [0].
The keypad will display a list of outputs that the
status may be viewed.
3. Using the [] and [] keys, highlight the output
that you want to view the status information, then
press [OK] to select. Alternatively, you can enter the
output number and then press [OK].
The keypad will display the following when the
output is off and OK:
External Siren Op1
Is OFF and Ready
Press OK or MENU
The keypad will display the following when the
output is off and missing:
External Siren Op1
Is OFF and Ready
Connection Trouble
Press OK or MENU
The keypad will display the following when the
output is ON and OK:
External Siren Op1
Is ON and Ready
Press OK or MENU
The keypad will display the following when the
output is ON and missing:
External Siren Op1
Is ON and Ready
Connection Trouble
Press OK or MENU
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Outputs > Commands >
Turn Output On/Off
MENU 4-0-1
This menu allows you to turn outputs that have been
programmed by your security company on or off. These
outputs can be programmed to control outside lighting,
pool pumps, watering systems etc.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [4] + [0] + [1].
If a valid PIN is required, the keypad will prompt you
to enter your PIN.
2. Use the [] and [] keys to select the output name
that you want to change, then press [OK] to select.
Alternatively, you can enter the output number,
then press [OK].
3. To toggle the output on or off, use the [ON] and
[OFF] keys.
The keypad will display the following when the
output is off:
External Siren Op1
Output is OFF,
To turn ON, Press ON.
To Go Back Press OK
To turn the output on, press [ON].

Table of Contents

Other manuals for Bosch Solution 6000-IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 6000-IP and is the answer not in the manual?

Bosch Solution 6000-IP Specifications

General IconGeneral
BrandBosch
ModelSolution 6000-IP
CategorySecurity System
LanguageEnglish

Related product manuals