In Operation | 7
0870211676_RA0760A_PLUS_-0004_IM_en 35 / 68
7.2.2 Pressure Control
The pressure control mode allows to maintain a constant pressure level (target pressure)
by automatically adapting the motor frequency. This mode is only available for “Role 2”
users, see Role and User [12].
To switch from speed control to pressure control:
Press on the target pressure value (password required).
Assign the target pressure in the keypad and press “Enter”.
Press on the switch button.
Speed control
Pressure control
Operating mode
On
Off
60 Hz
20 mbar
Parameter Default value Adjustment range
Pressure control (target pressure) 20 <5 … 400 mbar
For smooth process pressure control, it is required to adjust the PID parameters.
Refer to the specific document “Pump Control Instructions, art. no.: 0870213261” for
more details or contact your Busch representative.
NOTE
Display of the ultimate pressure.
Due to sensor accuracy, the minimum displayed value of the ultimate pressure is 5
mbar preceded by the symbol "<", which means that the actual value is lower than dis-
played.
The ultimate pressure of the machine is indicated on the nameplate (NP).