b) At the router# prompt, enter end and press Enter.
Step 3
Disconnect all the cables from the EPA.
Step 4
Loosen the captive screw in the center of the EPA by turning it counterclockwise.
Step 5
Slide the EPA out of the EPA slot.
Replacing an EPA
Procedure
Step 1
Locate the guide rails that hold the EPA in place.
Step 2
Align the EPA with the guide rails and carefully slide the EPA all the way all the way into the slot until the
EPA stops.
Step 3
Use a number 2 Phillips screwdriver to fully seat the EPA by turning the captive screw clockwise.
When fully seated, the EPA should be flush with the router faceplate.
Avoid overtorquing the EPA captive screw when installing the EPA. Tighten the captive screw on
the EPA to a torque of 11 +/-1 inch-pounds.
Note
Step 4
Restart the EPA using the following steps:
a) At the router# prompt, enter hw-module subslot 0/2 start and press Enter.
b) At the router# prompt, enter end and press Enter.
Step 5
Use the show platform command to verify whether the status of subslot 0/2 is OK.
Router# show platform
Chassis type: ASR1002-HX
Slot Type State Insert time (ago)
--------- ------------------- --------------------- -----------------
0 ASR1002-HX ok 00:07:52
0/0 BUILT-IN-EPA-8x1G ok 00:07:00
0/1 BUILT-IN-EPA-8x10G ok 00:07:00
0/2 EPA-18X1GE ok 00:07:01
.
.
.
Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router Hardware Installation Guide
130
Removing and Replacing FRUs
Replacing an EPA