To prevent overheating of the chassis, ensure that your system is drawing cool inlet air. Over temperature
conditions may occur if the system is drawing in the exhaust air of other equipment. Ensure adequate
clearance around the sides of the chassis so that cooling air can flow through the chassis interior unimpeded
and exhaust air exits the chassis and is not drawn into the inlet vent of another device.
Caution
Alarm Monitoring
The Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router display the CRIT, MAJ, and MIN alarm
indicator LEDs. The three system alarm LEDs on the Cisco ASR 1002-HX Router provide visual alarm
notification in the router. These LEDs indicate router status at all times, but you must directly observe these
LEDs to become aware of a router alarm condition. Additionally, you can use the show facility-alarm status
command to view the alarms.
Router# show facility-alarm status
System Totals Critical: 2 Major: 0 Minor: 0
Source Time Severity Description [Index]
------ ------ -------- -------------------
Power Supply Module 0 Jan 21 2016 18:06:16 CRITICAL Power Supply Failure [0]
Power Supply Bay 1 Jan 21 2016 18:06:15 CRITICAL Power Supply/FAN Module Missing
[0]
GigabitEthernet0/0/0 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [2]
GigabitEthernet0/0/1 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [2]
xcvr container 0/0/2 Jan 21 2016 18:08:21 INFO Transceiver Missing [0]
GigabitEthernet0/0/3 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [2]
GigabitEthernet0/0/4 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [2]
GigabitEthernet0/0/5 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [2]
GigabitEthernet0/0/6 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [2]
GigabitEthernet0/0/7 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [2]
TenGigabitEthernet0/1/0 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [36]
xcvr container 0/1/1 Jan 21 2016 18:08:21 INFO Transceiver Missing [0]
TenGigabitEthernet0/1/2 Jan 21 2016 18:08:21 INFO Physical Port Administrative
State Down [36]
xcvr container 0/1/3 Jan 21 2016 18:08:21 INFO Transceiver Missing [0]
.
.
.
There is no external alarm monitoring facility on the Cisco ASR 1002-HX Router.Note
To clear a visual alarm, you must resolve the alarm condition. The clear facility-alarm command does not
clear an alarm LED on the Cisco ASR 1001-HX Router or Cisco ASR 1002-HX Router. For example, if a
critical alarm LED is illuminated because an active EPA was removed without a graceful deactivation of the
EPA, the only way to resolve that alarm is to replace the EPA.
Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router Hardware Installation Guide
86
Power Up and Initial Configuration
Alarm Monitoring