EasyManuals Logo
Home>Cisco>Network Router>ASR 903

Cisco ASR 903 Installation Guide

Cisco ASR 903
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #135 background imageLoading...
Page #135 background image
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety, connect
the T1/E1 ports only to intra-building or unexposed wiring or cable. The intrabuilding cable must be shielded
and the shield must be grounded at both ends. The intra-building port(s) of the equipment or subassembly
must not be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are
designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE)
and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient
protection in order to connect these interfaces metallically to OSP wiring.
Warning
Patch Panel Connectors
The PANEL-48-1-DIN and PANEL-48-3-DIN provide 48 DIN 1.0/2.3 connectors on the front side of the
patch panel. These connectors terminate to 75 ohm coaxial cable through the DIN plug.
The PANEL-48-1-RJ48 provide 48 RJ45 connector on the front side of the patch panel. These connectors
terminate to 110 ohm T1/E1 cable through a RJ45 connector.
Figure 90: Patch Panel Connector on the Patch Panel
Figure 91: Patch panel Connector on the Interface Module
Recommended Patch Panel
We recommend using the following T1/E1 patch panels:
The following patch panels are introduced:
CABLE-16T1E1—Cable for 16-Port T1/E1 Interface Module, 12 feet
CABLE-32T1E1—Cable for 32-Port T1/E1 Interface Module
PANEL-16-BNC—Breakout panel with 16 T1/E1 75-ohm BNC ports
PANEL-32-RJ4—Breakout panel with 32 T1/E1 100/120- ohm RJ48 ports8
Also, the following patch panels are available from Optical Cable Corporation (http://www.occfiber.com).
48-port T1 RJ45 patch panel (part number DCC4884/25T1-S)
16-port E1 BNC patch panel (part number DCC16BNC/25T1-S)
To order a patch panel, contact the Sales and Marketing Support staff at Optical Cable Corporation:
Cisco ASR 903 and ASR 903U Aggregation Services Router Hardware Installation Guide
125
Installing the Cisco ASR 903 Router
Patch Panel Connectors

Table of Contents

Other manuals for Cisco ASR 903

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 903 and is the answer not in the manual?

Cisco ASR 903 Specifications

General IconGeneral
BrandCisco
ModelASR 903
CategoryNetwork Router
LanguageEnglish

Related product manuals