-40.8 VDCMinimum input voltage
-72 VDCMaximum input voltage
+12 VDCOutput voltage
8–10 AWG minimum for –48/–60 VDC.
Connector accepts 8 AWG maximum.
Wire gauge for DC input power connections
1200 W
975W with A903-FAN-E
Maximum power output
AC Power Specifications
The AC PSU models supported on the router are:
A900-PWR550-A—Provides 550 W output power for system 12 V power. Uses an IEC 320 C14 type
15 Amp power receptacle connector,
The A900-PWR550-A power supply can be used with the A900-RSP3C-400-S RSP modules only if the power
consumption is within 550 W. However, A900-PWR1200-A is recommended.
Table 3: AC Power Supply Specifications (A900-PWR550-A)
A900-PWR550-APart number
115VAC/ 230VACInput power specification
85/264 VACInput voltage
85 VACMinimum input voltage
264 VACMaximum input voltage
12VMinimum output voltage
Cisco ASR 903 and ASR 903U Aggregation Services Router Hardware Installation Guide