EasyManuals Logo
Home>Cisco>Firewall>Firepower 2120

Cisco Firepower 2120 User Manual

Cisco Firepower 2120
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Remove and Replace the SSD
Take note of the following warnings:
Statement 1030Equipment Installation
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1073No User-Serviceable Parts
No user-serviceable parts inside. Do not open.
Warning
Although the hardware supports removing and replacing SSDs while the system is running, the software does
not currently support hot swapping. You must power down the chassis to remove and replace SSDs.
The 100-GB SSD is restricted to the 2110 and 2120 models. The 200-GB SSD is restricted to the 2130
and 2140 models. Do not mix them.
Note
You can install a Malware Storage Pack (MSP) in slot 2. The MSP stores threat detection data for use in future
analysis. It supports the Advanced Malware Protection (AMP) software feature. It is used as both storage and
as the Malware application repository. RAID is not supported.
Cisco Firepower 2100 Series Hardware Installation Guide
45
Maintenance and Upgrades
Remove and Replace the SSD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 2120 and is the answer not in the manual?

Cisco Firepower 2120 Specifications

General IconGeneral
BrandCisco
ModelFirepower 2120
CategoryFirewall
LanguageEnglish

Related product manuals