A-21
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
78-6511-08
Appendix A System Messages
Error Message and Recovery Procedures
Error Message LRE_CPE-3-INVALIDPATCH: CPE on interface [chars] has invalid LRE
firmware.
Explanation
The LRE firmware header does not have a valid signature, or this firmware header
information is inconsistent with the firmware contents.
Recommended Action If the CPE is Cisco-certified, reapply the CPE firmware.
Error Message LRE_CPE-3-INVALIDPHY: CPE on interface [chars] has an unsupported
Ethernet PHY.
Explanation
The Ethernet PHY device on this CPE is not supported.
Recommended Action Cisco does not support this CPE device. Replace this CPE with one that is
supported.
Error Message LRE_CPE-3-INVALIDMODE: CPE on interface [chars] is in invalid mode
[chars].
Explanation
The CPE is in a mode that is inconsistent with its other characteristics, such as the model
number. The model number might imply a MAC mode while the CPE is in PHY mode.
Recommended Action Make sure that the CPE model number is correctly set. Also make sure that the
CPE has the correct LRE firmware and if applicable, that the CPE class identifier is correctly set.
Error Message LRE_CPE-SSNCHANGED: CPE unit on interface [chars] changed.
Explanation
The CPE system serial number changed. This usually means that the CPE unit on this
interface was replaced.
Recommended Action No action is required.
LRE_LINK Messages
This section contains the Long-Reach Ethernet link error messages.
Error Message LRE_LINK-3-UPDOWN: Interface [chars], changed state to [chars]
Explanation This message means that the link between the LRE port and the CPE device has been lost
and that no Ethernet traffic is being transferred. This could be the result of reconfiguring the port,
reconfiguring a profile in use by this port, a physical disconnection or reconnection of the LRE
connector on the switch, or by someone disconnecting the CPE LRE cable or cycling its power. It
might also be caused by any substantial interruption of the signal or cabling between the LRE port
and the CPE.
Recommended Action If someone is reconfiguring the port or the profile in use, ignore this message.
However, if the LRE link does not go back up within a minute or so, it could mean a physical
disconnection at the switch or CPE or a loss of power to the CPE.