115
How to set-up rental timer
This is a short guide for settings of rental timers. Please see following few steps how to set up rental timers:
Choose the type of rental timer
Rental Timer 1 (page 317) (based on engine running hours)
Rental Timer 2 (page 319) (based on date)
Adjust the length of chosen timer
Adjust the warning for user Rental Timer 1 Wrn (page 319) or Rental Timer 2 Wrn (page 321)(warning
will be displayed in alarmlist before elapsing of rental timer)
Adjust Rental Timer BOC (page 321) - common for both timers (if engine is still running after rental timer
counts down, this timer will starts count down and after elapse of timer the gen-set will be cooled down and
stop)
5.5.14 Service timers
Running hours counters
Service timers are used as maintenance interval counters. Counters can be set by setpoints - Maintenance
Timer 1 (page 219), Maintenance Timer 2 (page 220) and Maintenance Timer 3 (page 220). All of them
work the same way - their values are decremented every hour when the gen-set is running.
Actual value of counters is located either as the same setpoints Maintenance Timer 1 (page 219),
Maintenance Timer 2 (page 220) and Maintenance Timer 3 (page 220) or as values Maintenance 1 (page
469), Maintenance 2 (page 469) and Maintenance 3 (page 470).
When the value of counter reaches 0, the alarm Wrn Maintenance 1 (page 661) or Wrn Maintenance 2 (page
662) or Wrn Maintenance 3 (page 662) is active until the respective counter is readjusted back to nonzero
value.
Unused counter has to be adjusted to maximal value 10000 (Disabled).
5.5.15 Analog switches
There are logical analog function dedicated for analog switches. Each analog switch has setpoints for level ON
and level OFF and logical binary output.
Analog switch Setpoints Binary output
AIN SWITCH 01 (PAGE 624)
Analog Switch 1 On (page 243)
Analog Switch 1 Off (page 244)
AIN SWITCH01 (PAGE 553)
AIN SWITCH 02 (PAGE 624)
Analog Switch 2 On (page 246)
Analog Switch 2 Off (page 247)
AIN SWITCH02 (PAGE 553)
AIN SWITCH 03 (PAGE 624)
Analog Switch 3 On (page 249)
Analog Switch 3 Off (page 250)
AIN SWITCH03 (PAGE 554)
AIN SWITCH 04 (PAGE 625)
Analog Switch 4 On (page 252)
Analog Switch 4 Off (page 253)
AIN SWITCH04 (PAGE 554)
AIN SWITCH 05 (PAGE 625)
Analog Switch 5 On (page 255)
Analog Switch 5 Off (page 256)
AIN SWITCH05 (PAGE 555)

Table of Contents

Other manuals for ComAp InteliLite MRS16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliLite MRS16 and is the answer not in the manual?

ComAp InteliLite MRS16 Specifications

General IconGeneral
BrandComAp
ModelInteliLite MRS16
CategoryController
LanguageEnglish

Related product manuals