Dispenser on Hold. (No fuel will be dispensed).
The following End of Sale indicators are applicable to dispensers running in temperature compensation, fast fill,
or PED modes:
20
The pressure at the first measurement was within 20 bar of
the calculated maximum pressure.
Check for blockage in the fuel delivery hose,
breakaway or vehicle pipework.
21
The pressure at the second measurement exceeded the
calculated maximum pressure.
Check for blockage in the fuel delivery hose,
breakaway or vehicle pipework.
22
The pressure at the third measurement exceeded the
calculated maximum pressure.
Check for blockage in the fuel delivery hose,
breakaway or vehicle pipework.
26
Twin pressure sensor values (when fitted) do not agree.
Check pressure sensor calibration.