Troubleshooting
Problems When Dispenser is Idle
Compac Industries Ltd.
Page 75
www.compacngv.com
Problems When Dispenser is Idle
Problem
Likely Cause(s)
Recommended Action
After powering the dispenser,
PA:uSE is displayed and the
countdown from 60 doesn't start.
For push to start dispensers the start
button is held down.
Release the start button.
The nozzle is not stowed or the nozzle
switch is active.
Correctly stow the nozzle.
The dispenser pressure gauge
creeps past 200 bar when the
dispenser is not in use.
The regulator centre seal is damaged.
Replace the Regulator Valve Seals
(see page 52)
The solenoid piston seal is damaged.
Replace the Solenoid Valve Seal
(see page 48)
The C4000 electronics are not
working. The indicator LEDs are
off and nothing happens when
you lift the nozzle (i.e., no beeps
or 888888 is displayed).
Unacceptable voltage spikes are causing
the fuses on the C4000 to blow.
Fit a voltage-stabilising UPS to the
dispenser.
Replace the power supply fuses
(see page 60)
There is low input voltage.
Turn the dispenser off and then on
again.
Check the power supply connections
and input voltage to the dispenser
with a multimeter. A voltage-
stabilising UPS will be required.
The Output LED T10 is ON.
An error state exists.
Remedy the cause of the error (i.e.,
Display, Memory, or KG meter) by
checking the Fault Codes section
(see page 120).
Clear the error by quickly pressing
the start button or nozzle switch five
times to view the totes.
The watchdog LED D5 is
illuminated.
A processing fault has occurred.
Turn the power to the dispenser off
and then on again to reset the
watchdog.
If the light still illuminates, there is a
fault on the C4000 microprocessor
board, such as a loose memory chip
or a broken track.
Replace C4000 memory and
software chips
Replace C4000 processor board
A display LCD segment is
always on or always off.
Faulty display unit.
Replace Display PCB

Table of Contents