6.2.6  Measuring the exhaust gas values
Materials required
Exhaust gas analyser
Measuring the exhaust gas values
1.
Guide the measuring sensor (2) of the exhaust gas meter
(1) into the exhaust outlet (3) for the burner to be meas‐
ured.
2.
Measure the exhaust gas values.
Follow the operating instructions for the meter when taking
the readings.
Additional information:
If the meter indicates approx. 21% O
2
or nothing at all,
then the sensor is inside the wrong exhaust outlet.
3.
Wait 1 minute before taking the readings (4) and then
compare them with the specified limit; see 'Exhaust gas
values' under
'Gas specification' on page 132.
If the reading does not lie within the limit, the appliance
much be checked as directed in the adjustment instruc‐
tions in the service documentation.
Otherwise:
Continue with Step 4.
4.
Record the measurements.
6 Installation