At the start of work:
Empty and flush the steam generator
OSPOSC
Daily service and care
Operating Instructions OSC
The steam generator must be drained and flushed
manually before the start of work every day
with the CONVOTHERM switched off.
1. Open the water inlet.
2. Open the cap on the rear panel of the cooking
chamber by 2 to 3 turns.
3. When the pressure of the draining water
decreases, remove the cap completely.
4. Spray short water jets (2 to 4 seconds) into the
drain opening several times using the hand
shower.
5. Switch on the CONVOTHERM. Fresh water flows
through the steam generator.
6. Leave the CONVOTHERM switched on until the
water flowing through the generator is clear.
7. While the water is running, fit the cap again
and screw on finger tight
8. The steam generator is filled again automatically.
Caution when opening the cap!
Risk of scalding!
Operating Instructions OSP
We recommend that the automatic steam
generator flushing cycle be performed every day
immediately after switching on!
1. Switch on the CONVOTHERM.
2. The message ‘Flush steam generator?’ ‘Yes/No’
appears on the display.
3. The selection is already set to ‘Yes’. Press the
key to start the steam generator flushing.
4. If steam generator flushing is not wanted, select
‘No’ with the selector switch and confirm with
key . The steam generator flushing cycle
is then automatically terminated and the
CONVOTHERM is ready for the input of a cooking
programme. In this case, flushing of the steam
generator must be carried out later!
5. If the selection is not set to ‘No’ within
10 seconds, steam generator flushing is started
automatically.
6. The steam generator is drained, flushed and
then refilled. This process can take up to
5 minutes, depending on the size of the
CONVOTHERM. The CONVOTHERM is then
ready for operation.
For inspection, the steam generator can also be
drained and flushed manually via the steam gene-
rator drain plug as with the CONVOTHERM OSC.
Operating Instructions OSG
No flushing is necessary with the CONVOTHERM
OSG.
Daily flushing of the steam generator of your CONVOTHERM prolongs the service life of the steam
generator heater elements and prevents malfunctions.