xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
407
DGS-3420-28SC:admin#config external_alarm unit 2 channel 1 message External Alarm:
UPS is exhausted!
Command: config external_alarm unit 2 channel 1 message External Alarm: UPS is
exhausted!
Success.
DGS-3420-28SC:admin#
33-2 show external_alarm
Description
This command is used to display the status of the external alarm.
Format
show external_alarm {unit <unitlist>}
Parameters
unit - (Optional) Specifies the unit ID to be displayed.
<unit_id> - Enter the unit ID used here.
Restrictions
None.
Example
To display the real-time status of the external alarm:
DGS-3420-28SC:admin# show external_alarm
Command: show external_alarm
Unit Channel Status Message
------ --------- -------- ------------------------------------------
1 1 Normal External Alarm 1
1 2 Normal External Alarm 2