20
4ćremove the interconnect hose connected with the sump
The motor pump assembly is located under the tub behind the sump assembly. This
dishwasher model uses a capacitor start induction motor. The motor rotates clock- wise and
draws approximately 0.6 amp
Removal and Replacement
1. Disconnect power.
2. Remove the top panel, left side panel, right side panel, baseboard and bottom board
(see outside panel).
3. Label and disconnect the 2 terminals to the capacitor.
4. Label and disconnect the 2 terminals to the motor wire connector.
Caution: The clamp is easily damaged during removal and should not be reused. Replace the
old clamp with a new universal clamp.
5. Remove the clamp from the motor sump interconnect hose.
6. Remove the clamp from the motor main conduit interconnect hose.
Motor Pump Assembly
Capacitor
Hose