43
The parameters in the following section are READ
ONLY and cannot be changed by the user. They pro-
vide information for technicians and OEM users.
NOTE: the only parameters that can be configured are:
oEL, oEn, oEH.
These parameters allow OEMs to enter their own
product code.
7.12 Service Information / Ser
Danfoss ERC 102
Hold 3 sec: Menu
1 Click: Variable direct function, e.g.ECO/Night mode
1 Click: Variable direct function, e.g. light
Sub function: Up
1 Click: Temperature setpoint
Sub function: Down
Sub function: Back
Sub function: OK
ERC Front and Button Functionallity:
1 Click: Temperature setpoint
ERC
102 Reference manual – 7 PARAMETERS
ERC menu
code
Default Min Max Unit
Conv
Unit Scale Default Access
Shop Ser OEM
Service SEr
DI Sdi --- oFF on no -- R- R-
Voltage value uAC --- 0 270 no Vac 1 -- R- R-
DOs Status ouS --- IIII IIII no -- R- R-
Relay 1 counter rL1 --- 0 999 no 1000 1000 -- R- R-
Relay 2 counter rL2 --- 0 999 no 1000 1000 -- R- R-
Relay 3 counter rL3 --- 0 999 no 1000 1000 -- R- R-
Relay 4 counter rL4 --- 0 999 no 1000 1000 -- R- R-
interval Counter int --- 0 999 no min 1 -- R- R-
Defrost time counter dnt --- 0 999 no min 1 -- R- R-
Door open counter ont --- 0 999 no 1 1 -- R- R-
SW version Fir SWVER -32768 32767 no R- R- R-
HW version HAr HWVER -32768 32767 no R- R- R-
OrderNoLow OnL ORNOL -32768 32767 no -- -- --
OrderNoHigh OnH ORNOH -32768 32767 no -- -- --
OEM code Low oEL 0 0 999 no R- R- R-
OEM code Middle oEn 0 0 999 no R- R- R-
OEM code High oEH 0 0 999 no R- R- R-
Parameter version PAr PARVER -32768 32767 no R- R- R-
Last change CHA 0 0 999 no 1 -- -- --
Manufacturing date CHd 0 0 999 no 1 -- R- R-
Copy Key ID Cid 0 0 999 no 1 -- -- R-
Set as Default SFC no no yES no RW RW RW