8. Stop the prime mover, remove the pressure gauges, and return the system to its normal operating
configuration.
LS control adjustment
Gauge port M2
0 - 300 bar [0 - 4351 psi]
9/16-18
34-68 N•m
[25-50 lbf•ft]
Case drain port L1
0 - 10 bar [0 - 145 psi]
7/8-14
54 - 136 N•m
[40 - 100 lbf•ft]
LS adjusting plug
6 mm
LS set screw
4 mm
7.5 - 10.8 Nm [5.5 - 8 lbf•ft]
P104054
Adjusting plug, set screw, and gauge locations shown
Displacement Limiters
E Frame open circuit pumps are available with an optional adjustable displacement limiter. This
adjustable stop limits the pump’s maximum displacement.
Setting range
E100B 40 to 100 cm³ [2.44 to 6.1 in³]
E130B 70 to 130 cm³ [4.27 to 7.93 in³]
E147C 87 to 147 cm³ [5.31 to 8.97 in³]
Displacement per turn
E100B 8.4 cm³/rev [0.51 in³/rev]
E130B 8.4 cm³/rev [0.51 in³/rev]
E147C 8.4 cm³/rev [0.51 in³/rev]
Service Manual
Series 45 E Frame Open Circuit Pumps
Adjustments
©
Danfoss | September 2016 AX00000024en-US0401 | 27