VLT
®
5000 FLUX
Programming
■ Load and motor
■ Introduction
The parameter group 100 - 199 provides the adjustments and settings for load and motor connected to
the frequency converter.
PNU Parameter Factory setting Range Changes 4-Setup Conversion Data
# description during operation index type
100 Configuration Speed control, closed loop No Yes 0 5
101 Torque characteristics High - constant torque No Yes 0 5
102 Motor power Depends on the unit 0.18-500 kW No Yes 1 6
103 Motor voltage Depends on the unit 200 - 500 V No Yes 0 6
104 Motor frequency 50 Hz No Yes 0 6
105 Motor current Depends on the unit 0.01-I
VLT,MAX
No Yes -2 7
106 Rated motor speed Depends on the unit 100-60000 rpm No Yes 0 6
107 Automatic motor adaptation, AMA Adaptation off No No 0 5
115 Slip Compensating 100% -400% - +400% Yes Yes 0 3
116 Slip compensation time constant 0.50 sec. 0.05-5.00 sec. Yes Yes -2 6
119 High starting torque 0.0 sec. 0.0 - 0.5 sec. Yes Yes -1 5
120 Start delay 0.0 sec. 0.0 - 10.0 sec. Yes Yes -1 5
121 Start function Coasting in start delay time Yes Yes 0 5
122 Function at stop Coasting Yes Yes 0 5
123 Min. speed for activating function
at stop
0 rpm 0 - 600 rpm Yes Yes -1 5
124 DC holding current 50 % 0 - 100 % Yes Yes 0 6
125 DC braking current 50 % 0 - 160 % Yes Yes 0 6
126 DC braking time 10.0 sec. 0.0 - 60.0 sec. Yes Yes -1 6
127 DC brake cut-in speed Off 0.0-par. 202 Yes Yes -1 6
128 Motor thermal protection No protection Yes Yes 0 5
129 External motor fan No Yes Yes 0 5
130 Start speed 0.0 rpm 0.0 - 600 rpm Yes Yes -1 5
131 Initial current 0.0 Amp 0.0-par. 105 Yes Yes -1 6
150 Stator resistance Depends on unit Ohm No Yes -4 7
151 Rotor resistance Depends on unit Ohm No Yes -4 7
152 Stator leakage reactance Depends on unit Ohm No Yes -3 7
153 Rotor leakage reactance Depends on unit Ohm No Yes -3 7
154 Main reactance Depends on unit Ohm No Yes -3 7
156 Pole number 4-pole motor 2-100 No Yes 0 5
158 Ironloss resistance 10000 1 - 10000 No Yes 0 6
161 Minimum Inertia Depends on unit Kgm
2
No Yes -4 7
162 Maximum Inertia Depends on unit Kgm
2
No Yes -4 7
163 Functional stop delay 00–5secYesYes-17
164 Mech. brake release delay 0.5 sec 0.01 - 2.00 sec Yes Yes -2 U16
165 Mech. brake initial torque 20% +/- P221 Yes Yes -1 S16
166 Mech. brake initial direction [0] Clockwise [0] Clockwise
[1] Ref. dir.
Yes Yes 0 U8
167 Proportional gain boost, during
brake release
100% 0-400% Yes Yes 0 S16
✭ = factory setting. () = display text [] = value for use in communication via serial communication port
MG.55.A6.02 - VLT is a registered Danfoss trademark
67