Compact, AC line supply 3 x 525-600 V
According to international requirements VLT type 5032 5042 5052 5062
Normal overload torque (110 %):
Output current
I
VLT,N
[A] (550 V)
43 54 65 81
I
VLT, MAX
(60 s) [A] (550 V)
47
59 72 89
I
VLT,N
[A] (575 V)
41
52 62 77
I
VLT, MAX
(60 s) [A] (575 V)
45
57 68 85
Output
S
VLT,N
[kVA] (550 V)
41 51 62 77
S
VLT,N
[kVA] (575 V)
41
52 62 77
Typical shaft output
P
VLT,N
[kW]
30 37 45 55
Typical shaft output
P
VLT,N
[HP]
40 50 60 75
High overload torque (160 %):
Output current
I
VLT,N
[A] (550 V)
34 43 54 65
I
VLT, MAX
(60 s) [A] (550 V)
54
69 86 104
I
VLT,N
[A] (575 V)
32
41 52 62
I
VLT, MAX
(60 s) [A] (575 V)
51
66 83 99
Output
S
VLT,N
[kVA] (550 V)
32 41 51 62
S
VLT,N
[kVA] (575 V)
32
41 52 62
Typical shaft output
P
VLT,N
[kW]
22 30 37 45
Typical shaft output
P
VLT,N
[HP]
30 40 50 60
Max. cable cross-section to motor, 35 50 50 50
brake and load sharing [mm
2
]/[AWG]
2) 5)
2 1/0 1/0 1/0
Min. cable cross-section to motor, 10 16 16 16
brake and load sharing [mm
2
]/[AWG]
4)
8 6 6 6
Normal overload torque (110 %):
Rated input current
I
L,N
[A] (550 V)
42 53 63 79
I
L,N
[A] (600 V)
38 49 58 72
High overload torque (160 %):
Rated input current
I
L,N
[A] (550 V)
33 42 53 63
I
L,N
[A] (600 V)
30 38 49 58
Max. cable cross-section 35 50 50 50
power[mm
2
]/[AWG]
2) 5)
2 1/0 1/0 1/0
Max. pre-fuses
[-]/UL
1)
[A]
60 75 90 100
Efficiency
3)
0.96 0.96 0.96 0.96
Weight IP 20 EB [kg] 30 48 48 48
Power loss at max. load [W] 1074 1362 1624 2016
Enclosure IP 20/Nema 1
1. For type of fuse, see section Fuses.
2. American Wire Gauge.
3. Measured using 100 ft [30 m] shielded motor cables at rated load and rated frequency.
4. Min. cable cross-section is the smallest cable cross-section allowed to be fitted on the terminals to comply with IP 20. Always comply
with national and local regulations on min. cable cross-section.
5. Aluminum cables with cross-section above 0.054 in
2
[35 mm
2
] must be connected by use of an AI-Cu connector.
VLT
®
5000 Series
26 MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.

Table of Contents

Other manuals for Danfoss VLT 5003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5003 and is the answer not in the manual?

Danfoss VLT 5003 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5003
CategoryDC Drives
LanguageEnglish

Related product manuals