SFAVM - Stator Frequency Asyncron Vector Modulation
f
sw
(kHz)
130BB212.10
40
60
80
100
I
out
(A)
90
1 2 64
55°C
50°C
45°C
8 10
B2 all options
70
20
Illustration 6.19 Output current derating with switching
frequency and ambient temperature for enclosure types B2
and B4, SFAVM. Note: The graph is drawn with the current as
absolute value and is valid for both high and normal
overload.
6.2.6.3
Derating for Ambient Temperature,
Enclosure Types C
Enclosures C, T2, T4 and T5
60° AVM - Pulse Width Modulation
2
20%
4 6 8 10 12 14 16
40%
60%
80%
100%
110%
f
sw
(kHz)
45°C
50°C
55°C
130BA398.10
0
0
I
out
(%)
HO
C1 & C2
Illustration 6.20 Derating of I
out
for different T
AMB, MAX
for
enclosure types C1 and C2, using 60° AVM in High overload
mode (160% over torque)
130BA397.10
2
20%
4 6 8 10 12 14 16
40%
60%
80%
100%
110%
f
sw
(kHz)
0
0
I
out
(%)
NO
45°C
50°C
55°C
C1 & C2
Illustration 6.21 Derating of I
out
for different T
AMB, MAX
for
enclosure types C1 and C2, using 60° AVM in Normal overload
mode (110% over torque)
130BB831.10
80%
90%
100%
110%
(%)
l
out
C3 & C4
HO
2 4
6 8
20%
10
40%
60%
o
50 C
o
45 C
12 14
16
f
sw
(kHz)
Illustration 6.22 Derating of I
out
for different T
AMB, MAX
for
enclosure types C3 and C4, using 60° AVM in High overload
mode (160% over torque)
2 4
6 8
20%
10
40%
60%
80%
90%
100%
o
50 C
o
45 C
110%
12 14
16
o
55 C
f
sw
(kHz)
0
0
(%)
l
out
C3 & C4
NO
130BB829.10
Illustration 6.23 Derating of I
out
for different T
AMB, MAX
for
enclosure types C3 and C4, using 60° AVM in Normal overload
mode (110% over torque)
SFAVM - Stator Frequency Asyncron Vector Modulation
2
20%
4 6 8 10 12 14 16
40%
60%
80%
100%
110%
HO
f
sw
(kHz)
45°C
50°C
55°C
130BA400.10
0
0
I
out
(%)
C1 & C2
Illustration 6.24 Derating of I
out
for different T
AMB, MAX
for
enclosure types C1 and C2, using SFAVM in High overload
mode (160% over torque)
Product Specifications
VLT
®
AutomationDrive FC 301/FC 302 Design Guide, 0.25-75 kW
76 MG33BF02 - Rev. 2013-12-20
66

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals