37-14 Pos. Ctrl. Source
Selects the control source for positioning control.
Option: Function:
[0] * DI
[1] FieldBus
37-15 Pos. Direction Block
Use this parameter to congure whether to block a direction,
and the direction to be blocked.
Option: Function:
[0] * No Blocking
[1] Block Reverse
[2] Block Forward
37-16 Pos. Power Recovery
Congures whether to enable the power recovery function.
Option: Function:
[0] Disable
[1] * Enable
37-17 Pos. Ctrl Fault Behaviour
This parameter determines the behavior of the frequency
converter after a fault is detected.
Option: Function:
[0] * Ramp Down&Brake
[1] Brake Directly
37-18 Pos. Ctrl Fault Reason
READ-ONLY PARAMETER: The current fault reason of the alarm.
POSITION CTRL FAULT is displayed in this parameter.
Option: Function:
[0] * No Fault
[1] Homing Needed
[2] Pos. HW Limit
[3] Neg. HW Limit
[4] Pos. SW Limit
[5] Neg. SW Limit
[7] Brake Wear Limit
[8] Quick Stop
[9] PID Error Too Big
[12] Rev. Operation
[13] Fwd. Operation
[20] Can not nd home position
37-19 Pos. New Index
The currently latched index number.
Range: Function:
0* [0 - 255 ]
Parameter Descriptions
VLT
®
Midi Drive FC 280
112 Danfoss A/S © 12/2015 All rights reserved. MG07C102
44

Other manuals for Danfoss VLT Midi Drive FC 280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Midi Drive FC 280 and is the answer not in the manual?

Danfoss VLT Midi Drive FC 280 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Midi Drive FC 280
CategoryDC Drives
LanguageEnglish

Related product manuals