[4] >4.0 kHz<
[5] >5.0 kHz<
[6] >6.0 kHz<
[7] >8.0 kHz<
[8] >10.0 kHz<
[9] >12.0 kHz<
[10] >16.0 kHz<
15-** Drive Information
15-0* Operating Data
15-00 Operating hours
15-01 Running Hours
15-02 kWh Counter
15-03 Power Up's
15-04 Over Temp's
15-05 Over Volt's
15-06 Reset kWh Counter
15-07 Reset Running Hours Counter
15-3* Alarm Log
15-30 Alarm Log: Error Code
15-31 InternalFaultReason
15-4* Drive Identification
15-40 FC Type
15-41 Power Section
15-42 Voltage
15-43 Software Version
15-44 Ordered TypeCode
15-46 Drive Ordering No
15-47 Power Card Ordering No
15-48 LCP Id No
15-49 SW ID Control Card
15-50 SW ID Power Card
15-51 Drive Serial Number
15-53 Power Card Serial Number
15-9* Parameter Info
15-92 Defined Parameters
15-97 Application Type
15-98 Drive Identification
16-** Data Readouts
16-0* General Status
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference [%]
16-03 Status Word
16-05 Main Actual Value [%]
16-09 Custom Readout
16-1* Motor Status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor current
16-15 Frequency [%]
16-18 Motor Thermal
16-3* Drive Status
16-30 DC Link Voltage
16-33 Brake Energy /2 min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-38 SL Controller State
16-39 Control Card Temp.
16-5* Ref. & Feedb.
16-50 External Reference
16-52 Feedback[Unit]
16-57 Feedback [RPM]
16-6* Inputs & Outputs
16-60 Digital Input
16-61 Terminal 53 Setting
16-62 Analog Input 53
16-63 Terminal 54 Setting
16-64 Analog Input AI54
16-65 Analog Output 42 [mA]
16-66 Digital Output
16-67 Pulse Input 29[Hz]
16-68 Pulse Input 33 [Hz]
16-69 Pulse Output 27 [Hz]
16-70 Pulse Output 29 [Hz]
16-71 Relay Output [bin]
16-72 Counter A
16-73 Counter B
16-79 Analog Output AO45
16-8* Fieldbus & FC Port
16-86 FC Port REF 1
16-9* Diagnosis Readouts
16-90 Alarm Word
16-91 Alarm Word 2
16-92 Warning Word
16-93 Warning Word 2
16-94 Ext. Status Word
16-95 Ext. Status Word 2
18-** Data Readouts 2
18-9* PID Readouts
18-90 Process PID Error
18-91 Process PID Output
18-92 Process PID Clamped Output
18-93 Process PID Gain Scaled Output
22-** Appl. Functions
22-4* Sleep Mode
22-40 Minimum Run Time
22-41 Minimum Sleep Time
22-43 Wake-Up Speed [Hz]
22-44 Wake-Up Ref./FB Diff
22-45 Setpoint Boost
22-46 Maximum Boost Time
22-47 Sleep Speed [Hz]
22-6* Broken Belt Detection
22-60 Broken Belt Function
22-61 Broken Belt Torque
22-62 Broken Belt Delay
38-** Debug only
38-0* All debug parameters
38-00 TestMonitorMode
38-01 Version And Stack
38-02 Protocol SW version
38-06 LCPEdit Set-up
38-07 EEPROMDdataVers
38-08 PowerDataVariantID
38-09 AMA Retry
38-10 DAC selection
38-12 DAC scale
38-20 MOC_TestUS16
38-21 MOC_TestS16
38-23 TestMocFunctions
38-24 DC Link Power Measurement
38-25 CheckSum
38-30 Analog Input 53 (%)
38-31 Analog Input 54 (%)
38-32 Input Reference 1
38-33 Input Reference 2
38-34 Input Reference Setting
38-35 Feedback (%)
38-36 Fault Code
38-37 Control Word
38-38 ResetCountersControl
38-58 Inverter ETR counter
38-59 Rectifier ETR counter
38-60 DB_ErrorWarnings
38-61 Extended Alarm Word
38-69 AMA_DebugS32
38-74 AOCDebug0
38-75 AOCDebug1
38-76 AO42_FixedMode
38-77 AO42_FixedValue
38-78 DI_TestCounters
38-79 Protect Func. Counter
38-80 Highest Lowest Couple
38-81 DB_SendDebugCmd
38-82 MaxTaskRunningTime
38-83 DebugInformation
38-84 Debug Input Datas
38-85 DB_OptionSelector
38-86 EEPROM_Address
38-87 EEPROM_Value
38-88 Logger Time Remain
38-89 Emulator Version
38-90 LCP FC-Protocol select
38-95 DB_SimulateAlarmWarningExStatus
38-96 Data Logger Password
38-97 Data Logging Period
38-98 Signal to Debug
38-99 Signed Debug Info
User Interface and Programm...
VLT
®
AutomationDrive FC 360 Quick Guide
MG06A102 - VLT
®
is a registered Danfoss trademark 27