Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding
for the Code 11 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
Code 11 Set Length 1
This feature specifies one of the bar code lengths for Code 11 Length Control
on page 173. Length 1 is the minimum label length if in Variable Length on
page 173 Mode, or the first fixed length if in Fixed Length on page 173 Mode.
Length includes the bar code’s
check and data characters.
The length can be set from 2 to 50 characters. See "Set Length 1" on page 257
for more detailed programming instructions.
$CC1LC00
Code 11 Length Control = Variable Length
$CC1LC01
Code 11 Length Control = Fixed Length
DEFAULT
$CC1L1
Select Code 11 Set Length 1 Setting