If the tests fail, see Getting Help.
Troubleshooting The System Battery
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system
configuration information. This situation is caused by a defective battery.
1. Re-enter the time and date in the System Setup.
2. Turn off the system and disconnect it from the electrical outlet for at least one hour.
3. Reconnect the system to the electrical outlet and turn on the system.
4. Enter the System Setup.
If the date and time are not correct in the System Setup, check the SEL for system battery messages.
If the problem is not resolved, see Getting Help.
NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate
normally except for the time kept in the System Setup, the problem may be caused by software rather than by a
defective battery.
Troubleshooting Power Supplies
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Reseat the power supply by removing and reinstalling it.
NOTE: After installing a power supply, allow several seconds for the system to recognize the power supply and to
determine if it is working properly.
2. If the problem persists, see Getting Help.
Troubleshooting Cooling Problems
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Ensure that none of the following conditions exist:
System cover, cooling shroud, EMI filler panel, memory-module blank, or back-filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
A cooling fan is removed or has failed.
The expansion card installation guidelines have not been followed.
122

Table of Contents

Other manuals for Dell PE R720XD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PE R720XD and is the answer not in the manual?

Dell PE R720XD Specifications

General IconGeneral
Product TypeServer
Maximum Processors2
ChipsetIntel C600 series
Maximum Memory768GB
Memory Slots24
ProcessorIntel Xeon E5-2600 series
Memory TypeDDR3
Drive Bays12 x 3.5"
RAID SupportPERC H310
Power Supply750W or 1100W
Network ControllerBroadcom 5720
Expansion Slots7
Operating SystemWindows Server, Linux, VMware