Troubleshooting Your System 109
5
Ensure that each expansion card is firmly seated in its connector. See "Installing an Expansion Card"
on page 72.
6
Close the system. See "Closing the System" on page 47.
7
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem persists, go to the next step.
8
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
9
Open the system. See "Opening the System" on page 43.
10
Remove all expansion cards installed in the system. See "Removing an Expansion Card" in "Installing
System Components."
11
Close the system. See "Closing the System" on page 47.
12
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13
Run the appropriate online diagnostic test.
If the tests fail, see "Getting Help" on page 121.
14
For each expansion card you removed in step 10, perform the following steps:
a
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
b
Open the system. See "Opening the System" on page 43.
c
Reinstall one of the expansion cards.
d
Close the system. See "Closing the System" on page 47.
e
Run the appropriate diagnostic test.
If the tests fail, see "Getting Help" on page 121.
Troubleshooting the Microprocessor
Problem
Error message indicates a microprocessor problem.
A heat sink is not installed for the processor.
Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
1
If possible, run the appropriate online diagnostics test.
2
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3
Open the system. See "Opening the System" on page 43.

Table of Contents

Other manuals for Dell POWEREDGE 840

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell POWEREDGE 840 and is the answer not in the manual?

Dell POWEREDGE 840 Specifications

General IconGeneral
Processor SocketLGA 775
ChipsetIntel 3000
Memory Slots4 DIMM slots
Form FactorTower
ProcessorIntel Xeon
MemoryUp to 8GB DDR2
Drive Bays4 x 3.5" drive bays
StorageSATA
RAID SupportPERC 5/i
NetworkEmbedded Broadcom NetXtreme II 5708 Gigabit Ethernet
Expansion Slots2 PCI
Operating System SupportRed Hat Linux